Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38615155

RESUMO

The use of intravenous antiplatelet therapy during primary percutaneous coronary intervention (PPCI) is not fully standardized. The aim is to evaluate the effectiveness and safety of periprocedural intravenous administration of cangrelor or tirofiban in a contemporary ST-segment elevation myocardial infarction (STEMI) population undergoing PPCI. This was a multicenter prospective cohort study including consecutive STEMI patients who received cangrelor or tirofiban during PPCI at seven Italian centers. The primary effectiveness measure was the angiographic evidence of thrombolysis in myocardial infarction (TIMI) flow < 3 after PPCI. The primary safety outcome was the in-hospital occurrence of BARC (Bleeding Academic Research Consortium) 2-5 bleedings. The study included 627 patients (median age 63 years, 79% males): 312 received cangrelor, 315 tirofiban. The percentage of history of bleeding, pulmonary edema and cardiogenic shock at admission was comparable between groups. Patients receiving cangrelor had lower ischemia time compared to tirofiban. TIMI flow before PPCI and TIMI thrombus grade were comparable between groups. At propensity score-weighted regression analysis, the risk of TIMI flow < 3 was significantly lower in patients treated with cangrelor compared to tirofiban (adjusted OR: 0.40; 95% CI: 0.30-0.53). The risk of BARC 2-5 bleeding was comparable between groups (adjusted OR:1.35; 95% CI: 0.92-1.98). These results were consistent across multiple prespecified subgroups, including subjects stratified for different total ischemia time, with no statistical interaction. In this real-world multicenter STEMI population, the use of cangrelor was associated with improved myocardial perfusion assessed by coronary angiography after PPCI without increasing clinically-relevant bleedings compared to tirofiban.

2.
Atherosclerosis ; 366: 32-39, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36696749

RESUMO

BACKGROUND AND AIMS: Proprotein Convertase Subtilisin/Kexin type 9 inhibitors (PCSK9i) are recommended in patients at high and very-high cardiovascular (CV) risk, with documented atherosclerotic CV disease (ASCVD), and for very-high risk patients with familial hypercholesterolaemia not achieving LDL-cholesterol (LDL-C) goal while receiving maximally tolerated dose of lipid-lowering therapy (LLT). However, single country real-life data, reporting the use of PCSK9i in clinical practice, are limited. Therefore, we designed AT-TARGET-IT, an Italian, multicenter, observational registry on the use of PCSK9i in clinical practice. METHODS: All data were recorded at the time of the first prescription and at the latest observation preceding inclusion in the study. RESULTS: 798 patients were enrolled. The median reduction in LDL-C levels was 64.9%. After stratification for CV risk, 63.8% achieved LDL-C target; of them, 83.3% took LLTs at PCSK9i initiation and 16.7% did not. 760 patients (95.2%) showed high adherence to therapy, 13 (1.6%) partial adherence, and 25 (3.1%) poor adherence. At 6 months, 99.7% of patients enrolled in the study remained on therapy; there were 519 and 423 patients in the study with a follow-up of at least 12 and 18 months, respectively. Persistence in these groups was 98.1% and 97.5%, respectively. Overall, 3.5% of patients discontinued therapy. No differences in efficacy, adherence, and persistence were found between alirocumab and evolocumab. CONCLUSIONS: PCSK9i are safe and effective in clinical practice, leading to very high adherence and persistence to therapy, and achievement of recommended LDL-C target in most patients, especially when used as combination therapy.


Assuntos
Anticolesterolemiantes , Inibidores de Hidroximetilglutaril-CoA Redutases , Humanos , Inibidores de PCSK9 , LDL-Colesterol , Pró-Proteína Convertase 9 , Anticorpos Monoclonais/efeitos adversos , Anticolesterolemiantes/efeitos adversos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico
3.
Clin Case Rep ; 9(9): e04688, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34484752

RESUMO

Difficult diagnosis is due to rarity of the case. TT or TE echocardiography is sufficient to make a correct diagnosis. The risk of embolism or coronary ostia occlusion should guide the decision for surgery.

4.
J Interv Card Electrophysiol ; 61(3): 487-497, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32766944

RESUMO

BACKGROUND: Atrial activation during typical atrioventricular nodal reentrant tachycardia (AVNRT) exhibits anatomic variability and spatially heterogeneous propagation inside the Koch's triangle (KT). The mechanism of the reentrant circuit has not been elucidated yet. Aim of this study is to describe the distribution of Jackman and Haïssaguerre potentials within the KT and to explore the activation mode of the KT, in sinus rhythm and during the slow-fast AVNRT. METHODS: Forty-five consecutive cases of successful slow pathway (SP) ablation of typical slow-fast AVNRT from the CHARISMA registry were included. RESULTS: The KT geometry was obtained on the basis of the electroanatomic information using the Rhythmia mapping system (Boston Scientific) (mean number of points acquired inside the KT = 277 ± 47, mean mapping time = 11.9 ± 4 min). The postero-septal regions bounded anteriorly by the tricuspid annulus and posteriorly by the lateral wall toward the crista terminalis showed a higher prevalence of Jackman potentials than mid-postero-septal regions along the tendon of Todaro and coronary sinus (CS) (98% vs. 16%, p < 0.0001). Haïssaguerre potentials seemed to have a converse distribution across the KT (0% vs. 84%, p < 0.0001). Fast pathway insertion, as located during AVNRT, was mostly recorded in an antero-septal position (n = 36, 80%), rather than in a mid-septal (n = 6, 13.3%) or even postero-septal (n = 3, 7%) location. During typical slow-fast AVNRT, two types of propagation around the CS were discernible: anterior and posterior, n = 31 (69%), or only anterior, n = 14 (31%). During the first procedure, the SP was eliminated, and acute procedural success was achieved (median of 4 [3-5] RF ablations). CONCLUSION: High-density mapping of KT in AVNRT patients both during sinus rhythm and during tachycardia provides new electrophysiological insights. A better understanding and a more precise definition of the arrhythmogenic substrate in AVNRT patients may have prognostic value, especially in high-risk cases. TRIAL REGISTRATION: Catheter Ablation of Arrhythmias With High Density Mapping System in the Real World Practice (CHARISMA) URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ventricular , Fascículo Atrioventricular , Átrios do Coração , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
5.
J Arrhythm ; 36(5): 942-944, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33024475

RESUMO

Larger tip cryoablation catheters can dampen the signal at the distal tip reducing the resolution of mapping of supero paraseptal APs. The aid of high resolution mapping should be considered to improve safety and efficacy.

6.
Sensors (Basel) ; 14(10): 18268-85, 2014 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-25268920

RESUMO

We demonstrate the ability of Fiber Bragg Gratings (FBGs) sensors to protect large areas from unauthorized activities in railway scenarios such as stations or tunnels. We report on the technological strategy adopted to protect a specific depot, representative of a common scenario for security applications in the railway environment. One of the concerns in the protection of a railway area centers on the presence of rail-tracks, which cannot be obstructed with physical barriers. We propose an integrated optical fiber system composed of FBG strain sensors that can detect human intrusion for protection of the perimeter combined with FBG accelerometer sensors for protection of rail-track access. Several trials were carried out in indoor and outdoor environments. The results demonstrate that FBG strain sensors bonded under a ribbed rubber mat enable the detection of intruder break-in via the pressure induced on the mat, whereas the FBG accelerometers installed under the rails enable the detection of intruders walking close to the railroad tracks via the acoustic surface waves generated by footsteps. Based on a single enabling technology, this integrated system represents a valuable intrusion detection system for railway security and could be integrated with other sensing functionalities in the railway field using fiber optic technology.


Assuntos
Tecnologia de Fibra Óptica , Ferrovias/normas , Som , Análise de Falha de Equipamento , Humanos , Refratometria , Medidas de Segurança
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...